Back to Overview
Date May 08, 15
SIMCA®-online 13.1
SIMCA®-online 13
Problem

Execution ignores batch node start time and executes a batch with start time in the future (Q805)

Symptoms:

If a batch id exists in the batch node and has a start time in the future, the SIMCA®-online versions listed above fail to respect this start time and will start the real-time (normal) execution as soon as that batch id is found in the process data (as long as phase conditions are fulfilled).

Cause:

The execution logic was incorrect in regards to this.

Resolution:

Fixed in SIMCA®-online 13.2.

Workaround:

Avoid prepopulating the batch node too early. Improve the phase conditions so that those prevent the batch from starting prematurely.

More Information:

Only real-time (normal) execution of the configuration behaves as described above. Repredict execution always respect the batch start and end times of the batch node.


For more information about the SIMCA®-online server execution logic, see the SIMCA®-online Technical Guide.

icon-shopping-cart
Ready to Buy?